<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>47015</ErrorNumber>
<ErrorFamily>Punch</ErrorFamily>
<ErrorMessage>
PUN: Punch Motor &lt;MotorID - The punch motor that has timed out during the punch cycle&gt; has timed out while attempting a full cycle
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Activated punch motors are expected to complete their punch cycles in a
reasonable time (approximately 3 seconds).  Punch motors that take longer than
15 seconds to leave their home positions and return back to home (i,e, complete
one full cycle) will automatically attempt to retry the cycle up to four times.
If a timout occurs after and all retried the activation command fails with
this error.  This error could occur during either initialization or a normal
punch cycle.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Home sensor on punch motor is improperly calibrated
</Cause>
<Cause>
Home sensor signal in punch assembly and/or cabling is broken/shorted
</Cause>
<Parameter>
MotorID - The punch motor that has timed out during the punch cycle.
</Parameter>
<LastModified>
07-Jun-2006
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:51 2008 PST
</Updated>
<Links>
</Links>
</Error>